Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.100
Filtrar
1.
Radiographics ; 44(5): e230070, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38573814

RESUMO

For women undergoing mastectomy, breast reconstruction can be performed by using implants or autologous tissue flaps. Mastectomy options include skin- and nipple-sparing techniques. Implant-based reconstruction can be performed with saline or silicone implants. Various autologous pedicled or free tissue flap reconstruction methods based on different tissue donor sites are available. The aesthetic outcomes of implant- and flap-based reconstructions can be improved with oncoplastic surgery, including autologous fat graft placement and nipple-areolar complex reconstruction. The authors provide an update on recent advances in implant reconstruction techniques and contemporary expanded options for autologous tissue flap reconstruction as it relates to imaging modalities. As breast cancer screening is not routinely performed in this clinical setting, tumor recurrence after mastectomy and reconstruction is often detected by palpation at physical examination. Most local recurrences occur within the skin and subcutaneous tissue. Diagnostic breast imaging continues to have a critical role in confirmation of disease recurrence. Knowledge of the spectrum of benign and abnormal imaging appearances in the reconstructed breast is important for postoperative evaluation of patients, including recognition of early and late postsurgical complications and breast cancer recurrence. The authors provide an overview of multimodality imaging of the postmastectomy reconstructed breast, as well as an update on screening guidelines and recommendations for this unique patient population. ©RSNA, 2024 Test Your Knowledge questions for this article are available in the supplemental material.


Assuntos
Implantes de Mama , Neoplasias da Mama , Mamoplastia , Humanos , Feminino , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/cirurgia , Mastectomia/efeitos adversos , Mastectomia/métodos , Recidiva Local de Neoplasia/diagnóstico por imagem , Estudos Retrospectivos , Mamoplastia/efeitos adversos , Mamoplastia/métodos , Mamilos , Implantes de Mama/efeitos adversos , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/etiologia
2.
Medicine (Baltimore) ; 103(10): e37365, 2024 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-38457600

RESUMO

Controversies regarding the risk factors affecting direct-to-implant (DTI) immediate breast reconstruction still exist. This study aimed to evaluate the risk factors for severe complications in DTI breast reconstruction and explore potential salvage management strategies. We conducted a retrospective review of 238 patients (240 breasts) who underwent DTI immediate breast reconstruction between 2011 and 2020. Multivariate logistic regression analyses were used to identify the risk factors predicting severe complications. Seventeen (7.08%) reconstructed breasts experienced severe complications, of which only 5 were successfully salvaged through surgical revision, while the others failed and resulted in implant removal. Multivariate analyses demonstrated that mesh use [odds ratio (OR) = 4.054, 95% confidence interval: 1.376-11.945, P = .011] and post-mastectomy radiotherapy (odds ratio = 4.383, 95% confidence interval 1.142-16.819, P = .031) were independent predictors of severe complications. Mesh use and post-mastectomy radiotherapy for breast reconstruction increase the risk of severe complications. Despite positive surgical treatment, the successful salvage rate was poor.


Assuntos
Implantes de Mama , Neoplasias da Mama , Mamoplastia , Humanos , Feminino , Estudos Retrospectivos , Implantes de Mama/efeitos adversos , Neoplasias da Mama/radioterapia , Neoplasias da Mama/cirurgia , Neoplasias da Mama/complicações , Mastectomia/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/cirurgia , Mamoplastia/efeitos adversos , Mamoplastia/métodos , Fatores de Risco
3.
Int J Mol Sci ; 25(6)2024 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-38542137

RESUMO

Breast cancer is the most common cancer in women globally, often necessitating mastectomy and subsequent breast reconstruction. Silicone mammary implants (SMIs) play a pivotal role in breast reconstruction, yet their interaction with the host immune system and microbiome remains poorly understood. This study investigates the impact of SMI surface topography on host antimicrobial responses, wound proteome dynamics, and microbial colonization. Biological samples were collected from ten human patients undergoing breast reconstruction with SMIs. Mass spectrometry profiles were analyzed for acute and chronic wound proteomes, revealing a nuanced interplay between topography and antimicrobial response proteins. 16S rRNA sequencing assessed microbiome dynamics, unveiling topography-specific variations in microbial composition. Surface topography alterations influenced wound proteome composition. Microbiome analysis revealed heightened diversity around rougher SMIs, emphasizing topography-dependent microbial invasion. In vitro experiments confirmed staphylococcal adhesion, growth, and biofilm formation on SMI surfaces, with increased texture correlating positively with bacterial colonization. This comprehensive investigation highlights the intricate interplay between SMI topography, wound proteome dynamics, and microbial transmission. The findings contribute to understanding host-microbe interactions on SMI surfaces, essential for optimizing clinical applications and minimizing complications in breast reconstruction.


Assuntos
Anti-Infecciosos , Implantes de Mama , Neoplasias da Mama , Humanos , Feminino , Silicones , Implantes de Mama/efeitos adversos , Neoplasias da Mama/cirurgia , Proteoma , RNA Ribossômico 16S/genética , Mastectomia , Fibrose
4.
Int J Mol Sci ; 25(5)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38474119

RESUMO

There is extensive coverage in the existing literature on implant-associated lymphomas like anaplastic large-cell lymphoma, but breast implant-associated squamous cell carcinoma (BIA-SCC) has received limited scholarly attention since its first case in 1992. Thus, this study aims to conduct a qualitative synthesis focused on the underexplored association between breast implants and BIA-SCC. A systematic review was conducted utilizing the PubMed, Web of Science, and Cochrane databases to identify all currently reported cases of BIA-SCC. Additionally, a literature review was performed to identify potential biochemical mechanisms that could lead to BIA-SCC. Studies were vetted for quality using the NIH quality assessment tool. From an initial pool of 246 papers, 11 met the quality criteria for inclusion, examining a total of 14 patients aged between 40 and 81 years. BIA-SCC was found in a diverse range of implants, including those with smooth and textured surfaces, as well as those filled with saline and silicone. The condition notably manifested a proclivity for aggressive clinical progression, as evidenced by a mortality rate approximating 21.4% within a post-diagnostic interval of six months. Our literature review reveals that chronic inflammation, driven by various external factors such as pathogens and implants, can initiate carcinogenesis through epigenetic modifications and immune system alterations. This includes effects from exosomes and macrophage polarization, showcasing potential pathways for the pathogenesis of BIA-SCC. The study highlights the pressing need for further investigation into BIA-SCC, a subject hitherto inadequately addressed in the academic sphere. This necessitates the urgency for early screening and intervention to improve postoperative outcomes. While the review is confined by its reliance on case reports and series, it serves as a valuable reference for future research endeavors.


Assuntos
Implante Mamário , Implantes de Mama , Neoplasias da Mama , Linfoma Anaplásico de Células Grandes , Mamoplastia , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Feminino , Implantes de Mama/efeitos adversos , Implante Mamário/efeitos adversos , Mamoplastia/efeitos adversos , Neoplasias da Mama/patologia , Linfoma Anaplásico de Células Grandes/patologia
5.
Can J Surg ; 67(2): E108-E111, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38453352

RESUMO

SummaryThe House of Commons Standing Committee on Health proposed in 2022 to start a national registry for breast implants. Why, and what requirements are needed, will be outlined. Breast implant products are not always in compliance with international norms and standards, and several scandals have occurred because of industry fraud. To trace which patients have defective breast implants, a good registry is an absolute must. Furthermore, some diseases, such as lymphomas, autoimmune diseases, and so-called breast implant illness, are believed to be associated with breast implants. An accurate estimation of how often these diseases occur in patients with breast implants is lacking. A registry in which not only surgical data but also patient-reported outcome measurements are recorded will result in a better understanding of patient outcomes and device performance. The registry should not be a voluntary ("opt-in") registry but a mandatory ("opt-out") registry, in which only the patient (and not the surgeon) has the choice whether to participate.


Assuntos
Implante Mamário , Implantes de Mama , Mamoplastia , Humanos , Implantes de Mama/efeitos adversos , Implante Mamário/efeitos adversos , Sistema de Registros , Canadá
6.
Eur Radiol Exp ; 8(1): 36, 2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-38480588

RESUMO

BACKGROUND: Accurate assessment of breast implants is important for appropriate clinical management. We evaluated silicone properties and diagnostic accuracy for characterizing silicone implants and detecting degenerative changes including rupture in photon-counting computed tomography (PCCT). METHODS: Over 16 months, we prospectively included patients with silicone implants and available breast magnetic resonance imaging (MRI) who received thoracic PCCT performed in prone position. Consensus reading of all available imaging studies including MRI served as reference standard. Two readers evaluated all implants in PCCT reconstructions for degenerative changes. In a subgroup of implants, mean density of silicone, adjacent muscle, and fat were measured on PCCT reconstructions. Contrast-to-noise ratios (CNRs) were calculated for implant-to-muscle and implant-to-fat. RESULTS: Among 21 subjects, aged 60 ± 13.1 years (mean ± standard deviation) with 29 implants PCCT showed the following: high accuracy for linguine sign, intraimplant fluid (all > 0.99), peri-implant silicone (0.95), keyhole sign (0.90), and folds of the membrane (0.81); high specificity for linguine sign, intraimplant fluid, keyhole sign, folds of the membrane (all > 0.99), and peri-implant silicone (0.98); and high sensitivity for linguine sign and intraimplant fluid (all > 0.99). In a subgroup of 12 implants, the highest CNR for implant-to-muscle was observed on virtual unenhanced reconstructions (20.9) and iodine maps (22.9), for implant-to-fat on iodine maps (27.7) and monoenergetic reconstructions (31.8). CONCLUSIONS: Our findings demonstrate that silicone breast implants exhibit distinct contrast properties at PCCT, which may provide incremental information for detection of degenerative changes and rupture of implants. RELEVANCE STATEMENT: Thoracic photon-counting computed tomography is a promising modality for the diagnostic assessment of silicone breast implants. KEY POINTS: • Thoracic photon-counting computed tomography demonstrates unique contrast properties of silicone breast implants. • Iodine map reconstructions reveal strong contrast-to-noise ratios for implant-to-muscle and implant-to-fat. • Thoracic photon-counting computed tomography shows high diagnostic accuracy in detecting implant degeneration and rupture. TRIAL REGISTRATION: German Clinical Trials Register number DRKS00028997, date of registration 2022-08-08, retrospectively registered.


Assuntos
Implantes de Mama , Iodo , Humanos , Implantes de Mama/efeitos adversos , Projetos Piloto , Silicones , Tomografia Computadorizada por Raios X , Pessoa de Meia-Idade , Idoso , Feminino
7.
Breast J ; 2024: 9097040, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38444549

RESUMO

Background: Breast cancer with about 2.3 million diagnoses and 685,000 deaths globally is the most frequent malignancy in the female population. Continuous research has led to oncological and reconstructive advances in the management of breast cancer, thus improving outcomes and decreasing patient morbidity. Nowadays, the submuscular expander and prosthesis (E/P) implant-based breast reconstruction (IBR) accounts for 73% of all reconstructions. Despite its widely accepted efficacy, the technique is not free from complications and up to 28% of cases require revision surgery for mechanical complications such as capsular contracture, implant displacement/rotation, and implant rupture. With this study, the authors report their experience in the management of E/P IBR revision surgery through the technique of Selective Capsulotomies (SCs) and Partial Capsulectomy (PC). Methods: A retrospective study was conducted on patients who had previously undergone E/P IBR and presented for revision reconstruction between January 2013 and May 2023 at the Department of Plastic Surgery of the University of Siena, Italy. Reasons for revision included capsular contracture, implant displacement/rotation, and implant rupture. Revision reconstructions involved SC and PC with implant replacement. Fat grafting was also considered. The complication rate was evaluated by analysis of patients' medical records. Patients' satisfaction with the treatment was assessed through a specific questionnaire. Results: 32 patients underwent revision surgeries. No early complication occurred. Recurrence rate was assessed at 19% with average follow-up of 59 months (range: 13-114 months). The average time between revision surgery and recurrence was 3 years (range: 1-6 years). 23 patients answered the questionnaire and were overall satisfied with the treatments (8.29/10). Conclusions: SC possibly associated to PC is a valuable option for E/P IBR revision surgery with minimal complications, reduced surgical trauma, short operating time, and relatively low recurrence risk. In addition, treated patients are overall satisfied with the results over time.


Assuntos
Implantes de Mama , Neoplasias da Mama , Mamoplastia , Humanos , Feminino , Reoperação , Contratura Capsular em Implantes , Estudos Retrospectivos , Neoplasias da Mama/cirurgia , Mamoplastia/efeitos adversos , Implantes de Mama/efeitos adversos
8.
Int J Mol Sci ; 25(6)2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38542490

RESUMO

Breast Implant-Associated-Anaplastic Large Cell Lymphoma (BIA-ALCL) is a rare T-cell non-Hodgkin lymphoma associated with breast prosthetic implants and represents a diagnostic challenge. The National Comprehensive Cancer Network (NCCN) guidelines, updated in 2024, recommend for diagnosis an integrated work-up that should include cell morphology, CD30 immunohistochemistry (IHC), and flow cytometry (FCM). CD30 IHC, although the test of choice for BIA-ALCL diagnosis, is not pathognomonic, and this supports the recommendation to apply a multidisciplinary approach. A close collaboration between pathologists and laboratory professionals allowed the diagnosis of three BIA-ALCLs, presented as case reports, within a series of 35 patients subjected to periprosthetic effusions aspiration from 2018 to 2023. In one case, rare neoplastic cells were identified by FCM, and this result was essential in leading the anatomopathological picture as indicative of this neoplasm. In fact, the distinction between a lymphomatous infiltrate from reactive cells may be very complex in the cytopathology and IHC setting when neoplastic cells are rare. On the other hand, one limitation of FCM analysis is the need for fresh samples. In this study, we provide evidence that a dedicated fixative allows the maintenance of an unaltered CD30 expression on the cell surface for up to 72 h.


Assuntos
Implante Mamário , Implantes de Mama , Neoplasias da Mama , Linfoma Anaplásico de Células Grandes , Humanos , Feminino , Implantes de Mama/efeitos adversos , Linfoma Anaplásico de Células Grandes/diagnóstico , Linfoma Anaplásico de Células Grandes/etiologia , Linfoma Anaplásico de Células Grandes/patologia , Citometria de Fluxo , Implante Mamário/efeitos adversos , Exsudatos e Transudatos/metabolismo , Neoplasias da Mama/complicações
9.
Anticancer Res ; 44(2): 497-501, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38307560

RESUMO

BACKGROUND/AIM: To date, magnetic resonance imaging (MRI) remains the gold standard for diagnosing breast implant rupture. As MRI is an expensive procedure with limited availability, the improvement of sonographic assessment is desirable. A potentially useful tool in this regard is elastography. To evaluate the diagnostic benefits of strain elastography and shear wave elastography under standardized conditions we developed an animal model. MATERIALS AND METHODS: An animal model was created by preparing an implant site in a chicken breast, imitating tissue layers covering a breast implant after mastectomy. Different broken and intact implants were inserted. Thereby, measurements were performed using strain elastography and shear wave elastography. For strain elastography, the resulting images were investigated on repeated patterns. The data generated by shear wave elastography were analyzed for significant differences between the ruptured and intact implants. RESULTS: The animal model using chicken breast generated realistic images and measurements comparable to those of a human breast. Hence, ruptured and intact implants could be compared under standardized conditions. Statistical analysis showed no significant difference between intact and ruptured implants with respect to the data generated by shear wave elastography. Qualitative analysis using strain wave elastography showed different patterns between intact and ruptured implants in the animal model. Intact implants showed a characteristic sonographic image of three layers in certain levels. CONCLUSION: Shear wave elastography does not seem to produce reliable data for the evaluation of breast implants, whereas qualitative analysis using strain elastography might be a useful tool to improve diagnostic accuracy.


Assuntos
Implante Mamário , Implantes de Mama , Neoplasias da Mama , Técnicas de Imagem por Elasticidade , Humanos , Feminino , Implantes de Mama/efeitos adversos , Técnicas de Imagem por Elasticidade/métodos , Mastectomia , Sensibilidade e Especificidade
11.
J Plast Reconstr Aesthet Surg ; 90: 76-87, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38364672

RESUMO

INTRODUCTION: Implant-based breast augmentations and reconstructions are one of the most common surgical procedures performed by plastic surgeons in the United States, which has rapidly increased in popularity since the 2000s. Silicone lymphadenopathy (SL) is a complication of breast implants that involves migration of silicone to nearby soft tissue/lymph nodes. Data on its clinical features and management is scarce. METHODS: SL-related search terms were used to find articles in 3 databases. Of 598 articles, 101 studies met the inclusion criteria. Demographics, clinical presentation, workup, and management data were analyzed. RESULTS: Of 279 cases of SL and 107 with information on initial diagnosis, 35 (33%) were incidental. The most common symptom was painless lymphadenopathy, followed by painful lymphadenopathy. 251 (95%) and 13 (5%) patients had silicone and saline implants, respectively. 149 (68%) patients had implant rupture. Axillary lymphadenopathy was the most affected region (136 cases, 72%), followed by internal mammary (40 cases, 21%), cervical/supraclavicular (36 cases, 19%), and mediastinal (24 cases, 13%) regions. 25% of patients underwent fine-needle aspiration, 12% core needle biopsy, and 59% excisional biopsy. 32% of cases underwent explantation and/or implant exchange. The most common indication for surgery was implant rupture. Histology showed multinucleated giant cells, large histiocytes, and silicone accumulation. CONCLUSIONS: SL is a complication associated with breast implants. The majority of patients are asymptomatic, and most cases are managed conservatively. Minority need a biopsy and surgical interventions due to abnormal imaging, persistent symptoms, and/or implant rupture. Workup and management should be tailored to the patient.


Assuntos
Implante Mamário , Implantes de Mama , Linfadenopatia , Humanos , Géis de Silicone/efeitos adversos , Prevalência , Linfadenopatia/etiologia , Linfadenopatia/terapia , Implantes de Mama/efeitos adversos , Implante Mamário/efeitos adversos , Implante Mamário/métodos
14.
Life Sci Alliance ; 7(5)2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38383454

RESUMO

Breast implants are extensively employed for both reconstructive and esthetic purposes. However, the safety of breast implants with textured surfaces has been questioned, owing to a potential correlation with anaplastic large-cell lymphoma and the recurrence of breast cancer. This study investigates the immune response elicited by different prosthetic surfaces, focusing on the comparison between macrotextured and microtextured breast implants. Through the analysis of intraoperatively harvested periprosthetic fluids and cell culture experiments on surface replicas, we demonstrate that macrotextured surfaces elicit a more pronounced chronic-like activation of leucocytes and an increased release of inflammatory cytokines, in contrast to microtextured surfaces. In addition, in vitro fluorescent imaging of leucocytes revealed an accumulation of lymphocytes within the cavities of the macrotextured surfaces, indicating that the physical entrapment of these cells may contribute to their activation. These findings suggest that the topography of implant surfaces plays a significant role in promoting a chronic-like inflammatory environment, which could be a contributing factor in the development of lymphomas associated with a wide range of implantable devices.


Assuntos
Implante Mamário , Implantes de Mama , Neoplasias da Mama , Linfoma Anaplásico de Células Grandes , Humanos , Feminino , Implantes de Mama/efeitos adversos , Linfoma Anaplásico de Células Grandes/etiologia , Linfoma Anaplásico de Células Grandes/cirurgia
16.
Medicina (Kaunas) ; 60(2)2024 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-38399593

RESUMO

Background and Objectives: The surge in breast-related surgeries in Korea underscores the critical need for an accurate early diagnosis of silicone breast implant-related issues. Complications such as BIA-ALCL and BIA-SCC add complexity to breast health concerns, necessitating vigilant monitoring. Despite advancements, discrepancies persist between ultrasonographic and pathologic classifications of silicone implant ruptures, highlighting a need for enhanced diagnostic tools. This study explores the reliability of ultrasonography in diagnosing silicone breast implant ruptures and determining the extent of silicone migration, specifically with a focus on guiding potential capsulectomy based on pathology. Materials and Methods: A comprehensive review of medical records encompassing 5557 breast implants across 2790 patients who underwent ultrasound-assisted examinations was conducted. Among the screened implants, 8.9% (249 cases) were diagnosed with silicone breast implant rupture through ultrasonography. Subsequently, 89 women underwent revisional surgery, involving capsulectomy. The pathological analysis of 111 periprosthetic capsules from these cases aimed to assess the extent of silicone migration, and the findings were juxtaposed with the existing ultrasonographic rupture classification. Results: The diagnostic agreement between preoperative sonography and postoperative findings reached 100% for silicone breast implant ruptures. All eighty prosthetic capsules exhibiting a snowstorm sign in ultrasonography demonstrated silicone migration to capsules upon pathologic findings. Conclusions: High-resolution ultrasonography emerged as a valuable and reliable imaging modality for diagnosing silicone breast implant ruptures, with a notable ability to ascertain the extent of free silicone migration to capsules. This diagnostic precision is pivotal in informing decisions about potential capsulectomy during revisional surgery. The study advocates for an update to the current binary ultrasonographic classification, suggesting a more nuanced categorization into three types (subcapsular, intracapsular, and extracapsular) based on pathology.


Assuntos
Implantes de Mama , Feminino , Humanos , Implantes de Mama/efeitos adversos , Silicones/efeitos adversos , Sistemas Automatizados de Assistência Junto ao Leito , Reprodutibilidade dos Testes , Falha de Prótese , Ultrassonografia , Ruptura , Imageamento por Ressonância Magnética/métodos
17.
J Clin Invest ; 134(3)2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38299590

RESUMO

Breast implant illness (BII) is a poorly understood disease in which patients develop symptoms typical of autoimmune conditions following breast implantation. There is no known underlying cause, and patients often resort to breast implant removal and capsulectomy to alleviate symptoms. In this issue of the JCI, Khan and colleagues examined 86 breast explants from patients that reported BII symptoms and 55 control explants. The BII group showed a disproportionally high degree of biofilm, which was associated with oxylipin (10-HOME) on the implant surfaces. Injections of 10-HOME in the mammary fat pad of a murine model recapitulated BII symptoms and increased Th1 cell populations. Notably, macrophages in the periprosthetic tissue from BII patients were more likely to exhibit a proinflammatory phenotype, and naive T cells exposed to 10-HOME caused naive macrophages to differentiate to a proinflammatory phenotype. This work provides a pathophysiologic mechanism for a currently understudied and poorly characterized disease.


Assuntos
Implante Mamário , Implantes de Mama , Feminino , Humanos , Camundongos , Animais , Implantes de Mama/efeitos adversos , Oxilipinas , Biofilmes , Imunidade
18.
Ann Plast Surg ; 92(4S Suppl 2): S191-S195, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38319958

RESUMO

BACKGROUND: The use of irrigation with bacitracin-containing solution is common among surgeons, as it was widely thought to have antibacterial properties and prevent postoperative infection. Current literature, however, suggests that antibiotic-containing irrigation confers little added benefit. On January 31, 2020, the Food and Drug Administration instituted a ban on bacitracin-containing irrigation for operative use. This study aimed to determine whether bacitracin has a beneficial effect on postoperative infection rates by analyzing infection rates before and after the Food and Drug Administration ban on bacitracin irrigation. METHODS: A single-institution retrospective chart review was conducted. Eligible patients underwent implant-based breast reconstruction after mastectomy from October 1, 2016, to July 31, 2022. Procedure date, reconstruction type, patient comorbidities, use of bacitracin irrigation, postoperative infection, and secondary outcomes were collected. Univariate and multivariable logistic regression analyses were performed. RESULTS: A total of 188 female patients were included in the study. Bacitracin use did not protect against infection in univariate or multivariable analysis. Age greater than 50 years was associated with an increased risk of postoperative infection ( P = 0.0366). The presence of comorbidities, smoker status, neoadjuvant therapy treatment before surgery, implant placement, and laterality were all not significantly associated with postoperative infection development. CONCLUSIONS: The results of this study demonstrate a lack of association between bacitracin use and postoperative infection. Additional research into the optimal antibiotic for perioperative irrigation is needed, as bacitracin is not encouraged for use.


Assuntos
Implantes de Mama , Neoplasias da Mama , Mamoplastia , Humanos , Feminino , Pessoa de Meia-Idade , Bacitracina/uso terapêutico , Estudos Retrospectivos , Neoplasias da Mama/complicações , Mastectomia/efeitos adversos , Antibacterianos/uso terapêutico , Mamoplastia/métodos , Infecção da Ferida Cirúrgica/epidemiologia , Infecção da Ferida Cirúrgica/prevenção & controle , Infecção da Ferida Cirúrgica/etiologia , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/prevenção & controle , Implantes de Mama/efeitos adversos
19.
J Plast Reconstr Aesthet Surg ; 91: 128-134, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38417391

RESUMO

INTRODUCTION: As reconstructive surgeons have increasingly transitioned to the prepectoral plane for prosthetic breast reconstruction, the implications of mastectomy skin flap necrosis have become more concerning. Our goal was to evaluate the effect of skin flap necrosis on reconstructive outcomes in patients undergoing immediate prepectoral breast reconstruction. METHODS: A retrospective review was conducted of patients undergoing immediate two-stage prepectoral reconstruction at a single center with at least 3 months follow-up. Postoperative complications, reconstructive outcome, and time to final implant were compared between patients with and without mastectomy skin necrosis. RESULTS: A total of 301 patients underwent 509 prepectoral breast reconstructions. Forty-four patients (14.6%) experienced postoperative mastectomy skin flap necrosis. Demographic and reconstructive characteristics were similar between the necrosis and no necrosis cohorts. Patients with skin necrosis were more likely to undergo reoperation after tissue expander (64% vs 19%, p < 0.01) and undergo expander replacement (13.6% vs 3.5%, p = 0.02). However, rates of reconstructive failure (6.8% vs 6.2%), major infection (9.1% vs 9.0%), and minor infection (13.6% vs 17.5%) after expander placement were statistically similar. Patients with skin necrosis trended toward longer time before final implant placement, although the difference was not statistically significant (6.5 vs 5.0 months, p = 0.08). There was no difference in complication rates between the necrosis and no necrosis cohort after final implant placement. There was a higher rate of revision surgery after implant placement in the necrosis cohort (12.5% vs 4.1%, p = 0.047). CONCLUSIONS: Mastectomy skin flap necrosis is a concerning postoperative event, particularly in patients with prepectoral prostheses. We observed that patients with skin necrosis experience higher reoperation rates in the expander period, yet have similar infection rates and achieve similar final reconstructive outcomes compared to patients without necrosis.


Assuntos
Implante Mamário , Implantes de Mama , Neoplasias da Mama , Mamoplastia , Humanos , Feminino , Mastectomia/efeitos adversos , Neoplasias da Mama/cirurgia , Mamoplastia/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/cirurgia , Estudos Retrospectivos , Necrose/etiologia , Implantes de Mama/efeitos adversos , Implante Mamário/efeitos adversos
20.
J Cardiovasc Electrophysiol ; 35(4): 747-761, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38361241

RESUMO

INTRODUCTION: The implantation of a cardiac implantable electronic device (CIED) can have esthetic and psychological consequences on patients. We explore a heart team model for care coordination and discuss esthetic approaches for improved cosmetic outcomes in patients undergoing (CIED)-related procedures or de novo implantation. METHODS: Patients undergoing CIED surgery for approved indications between June 2015 and June 2022 were identified. Patients were included when surgical care was provided by a collaborative relationship between the primary electrophysiologist and the plastic surgeon. Patient demographics, details of the surgical procedure, information on breast implants, complications, and outcomes related to cosmesis were recorded. RESULTS: Twenty-two female patients were included in this study. The mean age was 50.2 ± 18.2 years. The mean follow-up duration was 2.2 ± 5.5 months. The top two indications for the procedure included CIED generator change (n = 9, 41%) and implantable cardioverter-defibrillator (ICD) implantation (n = 7, 32%). The most common reasons for involving plastic surgery in the procedure included surgery near breast implants (n = 10, 45%) and device displacement or discomfort (n = 8, 36%). CIED pocket position was prepectoral in 10 cases (45%), subpectoral in 11 patients (50%), and intramuscular in one patient (4.5%). The majority of the patients (20, 91%) had cosmetically acceptable results postprocedure. One patient (4.5%) had breast asymmetry on the CIED side, and another continued to have skin erosion over the CIED and leads. CONCLUSION: A heart team approach incorporating the expertize of cardiac electrophysiology and plastic surgery is essential for providing optimal care for patients with breast implants and patients requesting esthetic appeal.


Assuntos
Implantes de Mama , Procedimentos Cirúrgicos Cardíacos , Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Marca-Passo Artificial/efeitos adversos , Desfibriladores Implantáveis/efeitos adversos , Implantes de Mama/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...